Polycab – Rubber Cables

Polycab – Rubber Cables

As a trusted stockist, Mehta Electric Corporation supplies flexible and weather-resistant Rubber Cables, built to endure extreme temperatures, abrasion, and harsh industrial conditions while maintaining consistent electrical performance.

Rubber Cable Products Range

Rubber Cable as per IS 9968 Part-1 Power Cable

Construction

  • Conductor: Class 5 annealed tin electrolytic grade copper conductor as per IS 8130
  • Insulation : Special EPR compound equivalent to or better than IE2 as per IS 6380
  • Outer sheath: Special elastomeric compound based on PCP, CSP, NBR – PVC,CPE equivalent to or better than SE4, HOFR as per IS 6380.

Polycab Single core FR-LF wire is Eco & environment friendly to the environment

Technical SpecificationFeaturesWeight & Dimension
  • Rated Voltage: 1 .1 KV
  • AC Test Voltage : 3.0 KV

Working Temperature

  • Fixed Installation : – 40 Deg C to+ 90 Deg C
  • In Operation : – 25 Deg C to+ 90 Deg C

Excellent flexibility, Smooth finish, Enhanced resistance to Ozone, Oxygen, Heat, Solvent, Chemicals and Fire.

Nominal Cross Section Sq.mmNominal Thicknessof Insulation mmMax Cond. DC Resistance @ 20 Deg C Ohms/KmMax Temp. of the Cond. During Operation Deg CMax Temp. of the Cond. During Shot Circuit Deg COverall Diameter
1 Core2 Core3 Core4 Core
41.05.09902507.813.213.515.4
61.03.399025010.017.018.020.4
101.21.959025011.820.622.024.2
161.21.249025013.624.025.828.4
251.40.7959025015.729.231.434.2
351.40.5659025017.432.234.437.6
501.60.3939025020.237.239.843.6
701.60.2779025022.541.244.248.6
951.80.219025025.446.650.255.2
1201.80.1649025027.650.654.260.0
1502.00.1329025030.455.659.666.0
1852.20.1089025033.460.665.272.5
2402.40.08179025036.867.672.881.0
3002.60.06549025040.074.680.489.4
4002.80.04959025045.084.090.6100.8

Construction Diagram

Rubber Cable Generally as per IS 9968 Part – 1 Control Cable

Construction

  • Conductor: Class 5 annealed tin electrolytic grade copper conductor as per IS 8130.
  • Insulation: Special EPR compound equivalent to or better than IE2 as per IS 6380.
  • Outer sheath: Special elastomeric compound based on PCP, CSP, NBR-PVC,CPE equivalent to or better than SE4, HOFR as per IS 6380
Technical SpecificationFeaturesWeight & DimensionRange
  • Rated Voltage : 1 .1 KV
  • AC Test Voltage : 3.0 KV

Working Temperature

  • Fixed Installation : – 40 Deg C to+ 90 Deg C
  • In Operation : – 25 Deg C to+ 90 Deg C

Excellent flexibility, Smooth finish, Enhanced resistance to Ozone, Oxygen, Heat, Solvent, Chemicals and Fire.

Nominal Cross Section Sq.mmCORE NosNominal Thickness of Insulation mmMax Cond. DC Resistance @20 Deg C Ohms/KmMax Temp. of the Cond. During Operation Deg CMax Temp. of Cond. During Shot Circuit Deg COverall Diameter mm
1.571.013.79025014.6
1.5121.013.79025021.0
1.5241.013.79025029.0
2.571.08.219025016.0
2.5121.08.219025023.0
2.5241.05.099025031.5

2 Core upto 36.

Construction Diagram

Rubber Cable Generally as per IS 9968 Part – 1 with Reinforcement

Construction

  • Conductor: Class 5 annealed tin electrolytic grade copper conductor as per IS 8130.
  • Insulation: Special EPR compound equivalent to or better than IE2 as per IS 6380.
  • Bedding: Special elastomeric compound conforming to SE3 I SE4 as per IS 6380.
  • Reinforcement: Anti-torsional reinforcement between bedding and outer sheath.
  • Outer sheath: Special elastomeric compound based on PCP, CSP, NBR-PVC,CPE equivalent to or better than SE4, HOFR as per IS 6380.
Technical SpecificationFeaturesApplicationRange
  • Rated Voltage 1.1 KV
  • AC Test Voltage : 3.0 KV

Excellent flexibility, Smooth finish, Enhanced resistance to Ozone, Oxygen, Heat, Solvent, Chemicals and Fire.

Reeling & Unreeling application in dry, damp & wet locations as well as outdoors. As universal reeling cables for hoisting, transportation & handling equipment with heavy mechanical stresses, flexible wind energy cable.

Single core upto 400 Sq.mm, Multicore upto 240 Sq.mm, Control core 1.5 Sq.mm to 2.5 Sq.mm upto 36 core.

Construction Diagram

Rubber Cable Generally as per IS 9968 Part – 1 Fire Survival Cable

Construction

  • Conductor: Class 1 or 2 annealed tin or plain electrolytic grade copper conductor as per IS 8130.
  • Glass mica tape: Special glass mica tape suitable for 750°C or 950°C.
  • Insulation: Special EPA compound equivalent to or better than IE2 as per IS 6380
  • Bedding : Special Zero halogen elastomeric compound.
  • Fire barrier tape: High temperature resistance glass fibre tape
  • Braiding: Magnetic or non-magnetic metallic wire braiding.
  • Outer sheath: Special zero-halogen LSF (Low smoke & fume) elastomeric compound.
FeaturesTechnical SpecificationRange
  • Circuit intrigity test at 750°C or 950″C confirming to IEC 60331
  • Smoke density test conforming to AST MD 2843 or IEC 61034
  • Vertical flame spread test confirming to IEC 60332
  • Halogen acid gas test conforming to IEC-60754-1
  • Rated Voltage : 1 .1 KV
  • AC Test Voltage : 3.0 KV

Single core upto 630 Sq.mm, Multicore 2.5 Sq.mm to 240 sq mm.

Construction Diagram

Get in Touch