Polycab – Building Wires

Polycab – Building Wires

As a trusted stockist, Mehta Electric Corporation provides top-grade Building Wires, designed for safe and efficient electrical installations in residential, commercial, and industrial spaces, ensuring long-lasting performance and fire resistance.

Building Wires Products Range

Single Core FR-LF Cables

Applications:

Polycab Single core FR-LF wire is Eco & environment friendly to the environment & suitable for use where high flexibility is of Prime importance. This is also suitable for indoor and outdoor installation in industries, household appliances, power supply for refrigerators, air conditioners and building electrification.

FeaturesTechnical SpecificationWeight & Dimension
  • Flame Retardant
  • Smooth & glossy surface with enhanced lubrication properties
  • High Insulation Resistance
  • High abrasion Resistance
  • ROHS Complaint

Design

  • Plain annealed bunched circular copper conductor
  • Insulation: Flexible PVC compound

Core Identification

Red, Yellow, Blue, Black, Green (Customized colour can be provided)

Applicable Standard

  • IS 694 : 2010
  • IEC 60332 – 1 : 2004
  • ASTM 2863 : ASTM D2803-17

Approvals

  • IS 8130: 2013 BIS ISI
  • CE Mark

Cable Characteristics

  • Nominal Voltage (UO/U) : 600/1100 V
  • Max Operating Temperature : 70°C
  • Temperature Range : -15°C to + 70°C
  • Flame Resistant : ASTM D2863
  • Flammability : IEC 60332- 1:2004
  • Minimum Bending Radius : 8D
Nominal Area of Conductor SQ.mm.Max Diameter of each strandThickness of Insulation (Norn.) mm.Approx. Overall Diameter mm.Current Carrying Capacity* Rating Amps.Resistance (Max.) per Km. @20° Ohms
0.7524/0.210.62.57

26

114/0.310.72.81218.1
1.522/0.300.73.11612.1
2.536/0.300.83.8227.41
456/0.300.84.4294.95
684/0.300.85.2373.3
1080/0.411.05.8511.91
16126/0.401.06.8681.21

Cable Design / Type – FR-LF

Single Core FR-LF-LSH Cables

Applications:

Polycab Single core FR-LSH unsheathed insulated wire is suitable for residential wiring, either through embedded conduit or on the surface of the wall. The wire has enhanced flame resistant properties and low smoke generation hence it is suitable for use in all high rise buildings, malls and Hospitals.

FeaturesTechnical SpecificationWeight & Dimension
  • Flame Retardant
  • Low Smoke
  • Smooth & glossy surface with enhanced lubrication properties
  • High Insulation Resistance
  • High abrasion Resistance
  • ROHS Complaint

Design

  • Plain annealed bunched circular copper conductor
  • Insulation: Flexible PVC compound

Core Identification

Red, Yellow, Blue, Black, Green (Customized colour can be provided)

Applicable Standard

  • IS 694:2010
  • IEC 60332-1 : 2004
  • ASTM D2863
  • ASTM D2843-16
  • EC 60754-1 : 2011

Approvals

  • IS 8130: 2013 BIS ISI
  • CE Mark

Cable Characteristics

  • Nominal Voltage (UO/U) : 600/1100 V
  • Max Operating Temperature : 70°C
  • Temperature Range : -15°C to + 70°C
  • Oxygen Index : >29%
  • Smoke Density Rating : Max 60%
  • Acid Gas Generation : Max 20%
  • Flammability : IEC 60332 – 1
  • Minimum Bending Radius : 8D
Nominal Area of Conductor SQ.mm.Max Diameter of each strandThickness of Insulation (Norn.) mm.Approx. Overall Diameter mm.Current Carrying Capacity* Rating Amps.Resistance (Max.) per Km. @20° Ohms
0.7524/0.200.62.57

26

114/0.300.72.81218.1
1.522/0.300.73.11612.1
2.536/0.300.83.8227.41
456/0.300.84.4294.95
684/0.300.85.2373.3
1080/0.401.05.8511.91
16126/0.401.06.8681.21

Cable Design / Type – FR-LF-LSH

Single Core HR-FR-LF Cables

Applications:

Polycab Single core HR-FR-LF unsheathed wire is suitable for power supply in places where extra fire safety and heat Resistance is required like in high rise buildings, malls, hospitals & subways. This can be used either through embedded conduit or on the surface of the wall.

FeaturesTechnical SpecificationWeight & Dimension
  • Flame Retardant
  • Smooth & glossy surface With enhanced lubrication properties
  • High Insulation Resistance
  • High abrasion Resistance
  • Rohs Complaint

Design

  • Plain annealed bunched circular copper conductor
  • Insulation: Flexible PVC compound

Core Identification

Red, Yellow, Blue, Black, Green (Customized colour can be provided)

Applicable Standard

  • IS 694 : 2010
  • IEC 60332 – 1 : 2004
  • ASTM D2863 : 17a

Approvals

  • IS 8130: 2013 BIS ISI
  • CE Mark

Cable Characteristics

  • Nominal Voltage (UO/U) : 600/1100 V
  • Max Operating Temperature : 85°C
  • Temperature Range : -15°C to + 85°C
  • Flame Resistant : ASTM 2863
  • Flammability : IEC 60332 – 1
  • Minimum Bending Radius : 8D
Nominal Area of Conductor SQ.mm.Max Diameter of each strandThickness of Insulation (Norn.) mm.Approx. Overall Diameter mm.Current Carrying Capacity* Rating Amps.Resistance (Max.) per Km. @20° Ohms
0.7524/0.200.62.58.426
114/0.300.72.814.418.1
1.522/0.300.73.119.212.1
2.536/0.300.83.826.47.41
456/0.300.84.434.84.95
684/0.300.85.244.43.3
1080/0.401.05.861.21.91
16126/0.401.06.881.61.21

Cable Design / Type – HR-FR-LF

Get in Touch