Polycab – Building Wires
As a trusted stockist, Mehta Electric Corporation provides top-grade Building Wires, designed for safe and efficient electrical installations in residential, commercial, and industrial spaces, ensuring long-lasting performance and fire resistance.
Building Wires Products Range
Single Core FR-LF Cables
Applications:
Polycab Single core FR-LF wire is Eco & environment friendly to the environment & suitable for use where high flexibility is of Prime importance. This is also suitable for indoor and outdoor installation in industries, household appliances, power supply for refrigerators, air conditioners and building electrification.
Design
Core Identification
Red, Yellow, Blue, Black, Green (Customized colour can be provided)
Applicable Standard
Approvals
Cable Characteristics
| Nominal Area of Conductor SQ.mm. | Max Diameter of each strand | Thickness of Insulation (Norn.) mm. | Approx. Overall Diameter mm. | Current Carrying Capacity* Rating Amps. | Resistance (Max.) per Km. @20° Ohms |
|---|---|---|---|---|---|
| 0.75 | 24/0.21 | 0.6 | 2.5 | 7 |
26 |
| 1 | 14/0.31 | 0.7 | 2.8 | 12 | 18.1 |
| 1.5 | 22/0.30 | 0.7 | 3.1 | 16 | 12.1 |
| 2.5 | 36/0.30 | 0.8 | 3.8 | 22 | 7.41 |
| 4 | 56/0.30 | 0.8 | 4.4 | 29 | 4.95 |
| 6 | 84/0.30 | 0.8 | 5.2 | 37 | 3.3 |
| 10 | 80/0.41 | 1.0 | 5.8 | 51 | 1.91 |
| 16 | 126/0.40 | 1.0 | 6.8 | 68 | 1.21 |


Cable Design / Type – FR-LF
Single Core FR-LF-LSH Cables
Applications:
Polycab Single core FR-LSH unsheathed insulated wire is suitable for residential wiring, either through embedded conduit or on the surface of the wall. The wire has enhanced flame resistant properties and low smoke generation hence it is suitable for use in all high rise buildings, malls and Hospitals.
Design
Core Identification
Red, Yellow, Blue, Black, Green (Customized colour can be provided)
Applicable Standard
Approvals
Cable Characteristics
| Nominal Area of Conductor SQ.mm. | Max Diameter of each strand | Thickness of Insulation (Norn.) mm. | Approx. Overall Diameter mm. | Current Carrying Capacity* Rating Amps. | Resistance (Max.) per Km. @20° Ohms |
|---|---|---|---|---|---|
| 0.75 | 24/0.20 | 0.6 | 2.5 | 7 |
26 |
| 1 | 14/0.30 | 0.7 | 2.8 | 12 | 18.1 |
| 1.5 | 22/0.30 | 0.7 | 3.1 | 16 | 12.1 |
| 2.5 | 36/0.30 | 0.8 | 3.8 | 22 | 7.41 |
| 4 | 56/0.30 | 0.8 | 4.4 | 29 | 4.95 |
| 6 | 84/0.30 | 0.8 | 5.2 | 37 | 3.3 |
| 10 | 80/0.40 | 1.0 | 5.8 | 51 | 1.91 |
| 16 | 126/0.40 | 1.0 | 6.8 | 68 | 1.21 |


Cable Design / Type – FR-LF-LSH
Single Core HR-FR-LF Cables
Applications:
Polycab Single core HR-FR-LF unsheathed wire is suitable for power supply in places where extra fire safety and heat Resistance is required like in high rise buildings, malls, hospitals & subways. This can be used either through embedded conduit or on the surface of the wall.
Design
Core Identification
Red, Yellow, Blue, Black, Green (Customized colour can be provided)
Applicable Standard
Approvals
Cable Characteristics
| Nominal Area of Conductor SQ.mm. | Max Diameter of each strand | Thickness of Insulation (Norn.) mm. | Approx. Overall Diameter mm. | Current Carrying Capacity* Rating Amps. | Resistance (Max.) per Km. @20° Ohms |
|---|---|---|---|---|---|
| 0.75 | 24/0.20 | 0.6 | 2.5 | 8.4 | 26 |
| 1 | 14/0.30 | 0.7 | 2.8 | 14.4 | 18.1 |
| 1.5 | 22/0.30 | 0.7 | 3.1 | 19.2 | 12.1 |
| 2.5 | 36/0.30 | 0.8 | 3.8 | 26.4 | 7.41 |
| 4 | 56/0.30 | 0.8 | 4.4 | 34.8 | 4.95 |
| 6 | 84/0.30 | 0.8 | 5.2 | 44.4 | 3.3 |
| 10 | 80/0.40 | 1.0 | 5.8 | 61.2 | 1.91 |
| 16 | 126/0.40 | 1.0 | 6.8 | 81.6 | 1.21 |


Cable Design / Type – HR-FR-LF