EAPL – Protection Relays

EAPL – Protection Relays-Single phase preventers

Features

  • Resetting possible in manual mode from front button / rear terminals.

Applications

  • Motors, pumps, generators and Compressor panels and many more.

Ordering Information

1: Auto/Manual switch provided

EAPL – Protection Relays-Digital Version

Features

  • Displays instant values of specified parameters during healthy condition and type of fault during fault conditions
  • Programmable trip delay time and limits for each parameter
  • Relays NO/NC status during healthy condition – User Selectable.
  • Bypass option for undesired protection feature

Applications

  • Any 3 phase 4wire systems like motors, pumps, generators / distribution / MCC panels, air conditioners, elevators, cranes, escalators and many more.

Ordering Information

1: Panel Mounting | 2: Din rail mounting |3: Nominal current and inrush time user programmable. CT primary user selectable secondary default is 5 |
4: Displays the following parameters during healthiness by the following models:
a) PVMD/PVMD-G: 3-phase voltage L-L, L-N
b) PVIMD/PVIMD-G: 3-phase voltage L-L, L-N, Current L-N
c) PVIMD-R: 3-phase voltage L-L, L-N, Current L-N, frequency, PF, active power, active energy
d)PMR-01: 3-phase voltage L-L, L-N, Current L-N, frequency |
5: Monitors and displays the following parameters during unhealthiness by the following models.
a) PVMD, PVMD-G : Monitors and trips the circuit after the set trip delay time when ever power unhealthiness (phase failure, phase sequence, phase unbalance under voltage or over
voltage) occurs.
b) PVIMD, PVIMD-G, PVIMD-R: Monitors and controls any 3 phase 4 wire circuit after the set trip delay time when ever power unhealthiness (phase failure, phase sequence, phase unbalance under voltage, over voltage, under current or over current) occurs.
c) PMR-01: Monitors and trips the circuit after the set trip delay time when ever power unhealthiness (phase failure, phase sequence, phase unbalance under voltage, over voltage, under frequency, over frequency or earth leakage current, under current, over current) occurs.

EAPL – Protection Relays-Reverse Power Relay

Features

  • Displays instant values of specified parameters during healthiness and type of fault during fault conditions
  • Monitors and trips the circuit after the set trip delay time whenever any power unhealthiness (under voltage, over voltage & reverse power) occurs.

Applications

  • Solar Panel applications, Generator Panel and etc.

Ordering Information